Spirometer for PC use
Technical characteristics and basic parameters.
DEVICE
Portable spirometer recording the following parameters:
FVC, FEV1, FEV1/FVC%, FEV6, FEV6%, PEF, FEF25%, FEF50%, FEF75%, FEF25-75%, FET, Vext, FIVC, FIV1, FIV1/FIVC%, PIF, *FVC, *FEV1 , *PEF, VC, IVC, IC, ERV, FEV1/VC%, VT, VE, Rf, ti, te, ti/t-tot, VT/ti,
MVV (* = Best value).
Supplied with a reusable air turbine as well as a disposable air turbine where no calibration is required.
It applies directly to a USB communication port on the PC
No other connections or batteries are required
It has an internal temperature sensor for automatic BTPS (Body Temperature and Pressure Saturated) conversion.
PC SOFTWARE
Connect to a PC in real time (on line) with the user-friendly WinspiroPRO software
View flow/volume and volume/time graphs on the PC screen in real time.
Calculation of lung age.
Comparative spirometry before and after taking a bronchodilator (PRE-POST bronchodilator)
Full report of spirometry test results & corresponding printout.
Option to select environment for pediatric examination.
Patient database
Ability to export data and charts directly to e-mail.
Package includes: carrying case, WinspiroPRO software CD & USB cable.
Technical Characteristics:
Temperature sensor: semiconductor (0-45 ºC)
Flow Sensor: Bidirectional Digital Turbine
Flow Range: ± 16L/s
Volume Accuracy: ±3% or 50mL
Flow Accuracy: ±5% or 200mL/s
Dynamic Resistance at 12L/s: Communication Port: USB
Power Supply: USB Powered
Dimensions: 52 x 128 x 26 mm
Weight: 70 grams
OXIMETRY (SpO2) optional
Instantaneous as well as long (overnight) recording of oxygen saturation SpO2 and heart rate
Capable of adult and pediatric
recordings Sleep apnea detection with recording of desaturation events (ODI, NOD, T90%, T89% & T88% calculations)
6 minute walk test (6MWT) recording saturation oxygen SpO2 and heart rate via oximeter.
Selection of test recording (rest, load and, recovery etc)
Recording of oximetry using respiratory devices (oxygen, ventilator).
Detailed oximetry analysis with heart rate, minimum, maximum and average SpO2 parameters calculation.
Ability to display full oximetry waveforms via WinspiroPRO software
– SpO2 & heart rate display in real time.
– Statistical analysis to estimate saturation events.
– selection of printing charts
TECHNICAL CHARACTERISTICS OXIMETER Y
SpO2 measurement range: 0-99%
SpO2 measurement accuracy: 2% between 70-99% SpO2
Heart rate range: 30-254 BPM
Heart rate accuracy: 2 BPM or 2%.
Δημοσθένους 160 Καλλιθέα,
Τηλ : 210 9575358, Fax : 210 9585103
Αρ. ΓΕΜΗ: 5809301000
Email: sales@medair.gr